Introduction to Physiological Sensors
======================================
*How can we use technology to help diagnose disorders, improve athletic performance, and guide rehabilitation?* We will start to answer this question in this section of the tutorial by giving an overview of the sensors used to measure physiological information about the human body. By studying how strong muscles are, how much air the lungs can circulate, how fast the heart can pump blood throughout the body, and more, we can gain a better understanding of how the human body behaves and design tools that help people achieve their goals.
The information on each sensor will be organized as follows: first, we'll give a brief overview of what it's used for, then some instruction on how it is worn and what it measures (including reliability of the data), and perhaps most importantly, some discussion on what you could study or build using it.
---------------------------------------
Surface Electromyography: Delsys Trigno
---------------------------------------
**Surface electromyography (sEMG)** is a technique used to measure the electrical activity produced by the muscles. Muscles throughout the human body are activated in response to neural stimulation from the brain, and as they contract, they release an electrical impulse that circulates throughout bones and tissue. These impulses are captured by the sEMG sensor, and after applying some signal processing techniques that we'll see later in the :ref:`sensors_to_analysis` section, they can be incredibly useful in studying patterns in muscle activity.
^^^^^^^^^^^^^^^^^^^^^^^
Placement & Measurement
^^^^^^^^^^^^^^^^^^^^^^^
For the purposes of this tutorial, we'll be using the Delsys sEMG sensors, widely regarded for clinical-grade quality in research settings. Specifically, three of the most common products are the Trigno Avanti, Trigno Mini, and Trigno Quattro, as shown below.
.. image:: ../../images/Avanti_Calf.png
:width: 49 %
:alt: The Trigno Avanti sensor being worn by a patient in rehabilitation, on their legs.
.. image:: ../../images/Quattro_Face.png
:width: 49 %
:alt: The Trigno Mini sensor being worn by a professional pianist, on their arms and hands.
* The `Trigno Avanti `_ is the "standard" sEMG sensor.
* The `Trigno Mini `_ is a smaller form factor sensor, allowing you to get data from muscles that may be harder to reach with the Avanti.
* The `Trigno Quattro `_ is similar to the Trigno Mini, but there are four sensing heads, allowing you to get precise data from multiple locations.
Each of these devices also contains an **IMU (inertial measurement unit)** sensor, which consists of an **accelerometer** to measure acceleration and a **gyroscope** to measure orientation. This can be used in conjunction with the sEMG signal to understand the motion of the muscle. Finally, the devices also have LED lights on the top to indicate the status of the sensor.
In general, the following procedure can be used to apply the sensors to prepare for data collection:
* Clean the surface of the skin with an alcohol wipe before placing the sensor to remove any oils or contaminants which could interfere with the electrical signal.
* Remove the sensor from the base station and make the wireless connection (refer to the user manual for more details on the sensor connection and indicator lights).
* Prepare one of the adhesive tabs and place it on the back of the sensor. Then, peel off the other side to prepare to place it on the skin.
* To obtain high-quality data, place the sensor as close to the muscle as possible with the arrow in the direction of the muscle fibers (an example from the `Delsys Technical Notes on EMG Sensor Placement `_ is shown below). Once the correct location has been determined, stick the sensor to the skin --- and you're all set! Once you're done collecting data, simply peel it off and remove the adhesive tab.
.. image:: ../../images/trigno_placement.png
:width: 800
:alt: A diagram showing an EMG sensor being placed along the direction of the muscle fibers.
Traditionally, intramuscular electromyography (iEMG) is another technique used to measure muscle activity by sticking a needle inside the skin next to a particular muscle. While this is still used in some clinical applications, especially when muscles are deep into the skin or have a small cross-sectional area, it is losing popularity as it's more invasive for data collection.
Finally, an important concept in most sEMG applications is **maximum voluntary contraction (MVC)**. In order to measure muscle strength, especially in patients with neuromuscular disorders, we have the patient flex a certain muscle as much as they can and use the resulting sEMG value as a baseline. Then, all future readings are compared as a percentage of MVC.
^^^^^^^^^^^^
Applications
^^^^^^^^^^^^
As mentioned previously, sEMG can be used to study a wide variety of behaviors. Many of these applications involve developing machine learning algorithms for automated classification based on sEMG signals, though this is not necessarily the only use case. The following examles illustrate the versatility of sEMG:
* It can help diagnose certain muscular disorders, including muscular dystrophy and chronic pain [#]_ [#]_.
* It can help identify nerve dysfunction and muscle fatigue [#]_ [#]_ [#]_ [#]_.
* It can be used as a control signal for prosthetic and other robotic devices [#]_ [#]_ [#]_.
* It can be used to help understand human motions via the collection of large-scale sEMG datasets to train machine learning algorithms [#]_ [#]_.
---------------------
Heart Rate: Polar H10
---------------------
**Heart rate (HR) sensors** are used to record the rate at which the heart pumps blood throughout the body, measured as the number of contractions (beats) per minute (bpm). Various factors can affect a person's heart rate, including fitness, stress, diet, genetics, medications, or disease/illness. The average HR for a normal, healthy person is between 60-100 bpm at rest, and that could drop to 40 bpm or lower for endurance athletes.
**Heart rate variability (HRV)** is a measure of the variation in time (milliseconds) between consecutive heartbeats. The heartbeat isn't exactly regular all the time, so HRV serves as an indicator for how well your body can respond to stress or exercise. It's usually measured over a period of at least five minutes, and a higher value is better as it indicates that the heart can recover faster.
HR and HRV are widely considered as essential metrics for understanding human health and performance.
^^^^^^^^^^^^^^^^^^^^^^^
Placement & Measurement
^^^^^^^^^^^^^^^^^^^^^^^
For this tutorial, we will focus on the `Polar H10 `_ HR sensor. The device is worn around the chest (typically under the shirt), with a pad placed close to the heart and held in place via a buckle and strap. This relatively unobtrusive design makes it ideal for measuring HR during intense exercise. An example of wearing the device is shown below (image from the `Polar blog `_).
.. image:: ../../images/polarh10.jpg
:width: 800
:alt: The Polar H10 device being worn around a man's chest.
The Polar H10 is an example of an **electrocardiograph**, which is a type of HR sensor that measures the electrical potential of the heart's activity. We refer to the resulting electrical signal as an **electrocardiogram (ECG, or EKG)**. A typical ECG is shown below (figure from [#]_). You can find a detailed description in the paper, but for now, just know that it shows the stages of depolarization and repolarization (changes in electric charge distribution) of different parts of the heart. In particular, notice the **RR interval** on the graph: the time (seconds) between two successive R peaks. To calculate the heart rate, simply divide 60 (seconds per minute) by the RR interval. We'll explore this process further in :ref:`sensors_to_analysis`.
.. image:: ../../images/ecg_graph.png
:width: 800
:alt: Graph of a typical electrocardiogram, with parts of the waveform labeled.
^^^^^^^^^^^^^^^^^^^^^^^^^^
Reliability & Alternatives
^^^^^^^^^^^^^^^^^^^^^^^^^^
There are many other techniques used for measuring HR. One common example is **photoplethysmography (PPG)**, which uses LED lights to detect blood volume changes underneath the skin. You've probably seen this on many different kinds of fitness/smart watches, where it's often used for monitoring exercise or sleep. These devices are convenient because they're easier to wear than the chest strap, and in most cases, their accuracy is comparable to the chest strap ECG. However, many studies have concluded that PPG is not as accurate as ECG during high-intensity activities, or when clinically assessing HRV [#]_ [#]_ [#]_, though some have shown that they may be acceptably close in certain applications [#]_ [#]_.
Studies [#]_ [#]_ have shown that the Polar H10 chest strap device is comparably accurate to the Holter medical-grade ECG. As such, these wearable sensors are considered the gold standard when it comes to commercial HR sensing.
^^^^^^^^^^^^
Applications
^^^^^^^^^^^^
As we've discussed, there are a wide variety of clinical and fitness-related applications for HR and HRV sensing. We won't attempt to provide an exhaustive list here, but just to get you thinking, here a few mobile and virtual reality applications that integrate heart rate feedback [#]_ [#]_ [#]_ [#]_. We'll explore this more in :ref:`sensors_to_int`.
---------------------------
Muscle Oxygen: Moxy Monitor
---------------------------
A **muscle oxygen sensor** is used to measure the saturation of oxygen levels (SmO\ :sub:`2`\) within various muscle groups in the human body. It represents the percentage of hemoglobin that is carrying oxygen in muscle tissue, and can be thought of as a measure of balance between supply and demand for oxygen in the muscle. During low intensity activity, SmO\ :sub:`2`\ generally increases as the heart rate increases and blood vessels dilate, allowing for more blood flow; conversely, during high intensity activity, SmO\ :sub:`2`\ drops as the heart struggles to keep up supplying oxygen to the muscles.
For more information on SmO\ :sub:`2`\ (and the sources of the information here), please refer to the Moxy website for a `scientific explanation `_ and `the physiology surrounding training zones `_.
^^^^^^^^^^^^^^^^^^^^^^^
Placement & Measurement
^^^^^^^^^^^^^^^^^^^^^^^
For our tutorial, we'll use the `Moxy monitor `_. They sell compression shorts with the sensor attached, and you can also tuck the sensor under your own shorts or strap it elsewhere on the skin using tape or adhesive. An example of wearing the device is shown below (image from `Moxy `_).
.. image:: ../../images/moxy.jpg
:width: 800
:alt: Left: the Moxy monitor being worn on a runner's leg. Right: Close-up view of attaching the Moxy monitor.
The Moxy sensor uses **near-infrared spectroscopy (NIRS)**, which is a system that sends near-infrared light through some medium and measures the light reflected back with a photodetector. Since oxygenated and deoxygenated hemoglobin absorb different amounts of light at different wavelengths, a measurement of SmO\ :sub:`2`\ can be obtained based on differences in reflectance. Again, refer to the `scientific explanation `_ for more details.
^^^^^^^^^^^^
Applications
^^^^^^^^^^^^
Muscle oxygen saturation is gaining popularity as a tool for physiological research. See some examples below:
* It is used in sports science, most notably cardiovascular exercise but also a wide variety of other activities, to assess performance and tailor training programs [#]_ [#]_ [#]_ [#]_.
* It can be used to help assess the effects of exercise in patients with cardiovascular [#]_ [#]_ [#]_ and neuromuscular [#]_ diseases.
----------------------------------
Oxygen Volume: VO2 Master Analyzer
----------------------------------
**Oxygen volume** (VO\ :sub:`2`\) sensors are used to measure oxygen consumption during aerobic and anaerobic physical activity. This information is crucial for determining levels of cardiovascular fitness and can be used to design personalized training regimens for athletes.
^^^^^^^^^^^^^^^^^^^^^^^
Placement & Measurement
^^^^^^^^^^^^^^^^^^^^^^^
For our tutorial, we'll be using the `VO2 Master Analyzer `_. The device is composed of a face mask strapped around the head. The mask works by measuring the oxygen and carbon dioxide concentration of air coming into and going out of the body. An example of someone wearing the VO2 Master Analyzer is shown below (image from `VO2 Master `_).
.. image:: ../../images/vo2master.jpg
:width: 600
:alt: The VO2 Master Analyzer face mask being worn by a woman on an indoor exercise bike.
The most important facet of oxygen volume sensing is **maximal oxygen consumption** (VO\ :sub:`2`\max), which is the maximum amount of oxygen that an individual can utilize during intense exercise. This is determined by two factors: the amount of blood the heart can pump per beat and the efficiency with which the muscles can use the oxygen extracted from that blood. Further testing can reveal **ventilatory thresholds**, which are certain inflection points of the body's performance during exercise. During the earlier stages of intensity (before the first threshold, VT1), ventilation increases linearly with oxygen consumption, but at higher stages (between thresholds and after the second threshold, VT2), the increase becomes disproportionate to oxygen consumption. Visit the `VO2 Master Blog Series `_ for more information on VO\ :sub:`2`\max and its use in fitness.
^^^^^^^^^^^^
Applications
^^^^^^^^^^^^
As mentioned above, oxygen volume sensing is used in a variety of applications related to cardiovascular fitness. Included below are several example use cases:
* It can be used to design and compare the effectiveness of training regimens for endurance athletes [#]_ or the general population [#]_, especially for high-intensity interval training (HIIT). It was also shown as a potentially accurate measure of caloric expenditure in atheletes [#]_.
* It can be used to assess the impacts of musculoskeletal disorders and other chronic pains [#]_ [#]_ [#]_.
---------------
Section Review
---------------
In this section, you were introduced to four different types of physiological sensors. You learned about what data on the human body we can use to assess performance, and how sensors are designed to capture that data. You were also exposed to some of the active research in human health and performance that uses these sensors. All of this will be an important background for the next sections, where we'll take a deep dive into the process of collecting, presenting, and analyzing this data. Keep up the good work!
^^^^^^^^^^^^^^^^^^^^^^^
Module Self-Assessment
^^^^^^^^^^^^^^^^^^^^^^^
.. quizdown::
---
shuffle_answers: false
---
## Which of the following sensors is used to measure heart rate?
> Re-read the sections on each sensor.
1. [ ] Moxy Monitor
> The correct answer is Polar H10.
2. [x] Polar H10
3. [ ] Delsys Trigno
> The correct answer is Polar H10.
4. [ ] VO2 Master Analyzer
> The correct answer is Polar H10.
## Which of the following sensors is used to measure surface electromyography?
> Re-read the sections on each sensor.
1. [ ] Moxy Monitor
> The correct answer is Delsys Trigno.
2. [ ] Polar H10
> The correct answer is Delsys Trigno.
3. [x] Delsys Trigno
4. [ ] VO2 Master Analyzer
> The correct answer is Delsys Trigno.
## Which of the following sensors is used to measure muscle oxygen saturation levels?
> Re-read the sections on each sensor.
1. [x] Moxy Monitor
2. [ ] Polar H10
> The correct answer is Moxy Monitor.
3. [ ] Delsys Trigno
> The correct answer is Moxy Monitor.
4. [ ] VO2 Master Analyzer
> The correct answer is Moxy Monitor.
## Which of the following sensors is used to measure oxygen consumption?
> Re-read the sections on each sensor.
1. [ ] Moxy Monitor
> The correct answer is VO2 Master Analyzer.
2. [ ] Polar H10
> The correct answer is VO2 Master Analyzer.
3. [ ] Delsys Trigno
> The correct answer is VO2 Master Analyzer.
4. [x] VO2 Master Analyzer
----------
References
----------
^^^^^^^^^^^^^^^^^^^^^^^^
Surface Electromyography
^^^^^^^^^^^^^^^^^^^^^^^^
.. [#] M.F. Antwi-Afaria, H. Lib, D.J. Edwardsc, E.A. Pärnc, J. Seod, and A.Y.L. Wong. "Biomechanical analysis of risk factors for work-related musculoskeletal disorders during repetitive lifting task in construction workers." *Automation in Construction*, vol. 83, pp. 41-47, Nov. 2017, doi: 10.1016/j.autcon.2017.07.007.
.. [#] \D. Barmpakos, P. Kaplanis, S.A. Karkanis, and C. Pattichis. "Classification of neuromuscular disorders using features extracted in the wavelet domain of sEMG signals: a case study." *Health and Technology*, vol. 7, pp. 33-39, 2017, doi: 10.1007/s12553-016-0153-3.
.. [#] \S. Wang, H. Tang, B. Wang, and J. Mo. "A Novel Approach to Detecting Muscle Fatigue Based on sEMG by Using Neural Architecture Search Framework." *IEEE Transactions on Neural Networks and Learning Systems*, vol. 34, no. 8, pp. 4932-4943, Aug. 2023, doi: 10.1109/TNNLS.2021.3124330.
.. [#] \G. Venugopal, M. Navaneethakrishna, and S. Ramakrishnan. "Extraction and analysis of multiple time window features associated with muscle fatigue conditions using sEMG signals." *Expert Systems with Applications*, vol. 41, no. 6, pp. 2652-2659, May 2014, doi: 10.1016/j.eswa.2013.11.009.
.. [#] \M. Shariatzadeh, E.H. Hafshejani, C.J. Mitchell, M. Chiao, and D. Grecov. "Predicting muscle fatigue during dynamic contractions using wavelet analysis of surface electromyography signal." *Biocybernetics and Biomedical Engineering*, vol. 43, no. 2, pp. 428-441, Jun. 2023, doi: 10.1016/j.bbe.2023.04.002.
.. [#] \S. Huang, S. Cai, G. Li, Y. Chen, K. Ma, and L. Xie. "sEMG-Based Detection of Compensation Caused by Fatigue During Rehabilitation Therapy: A Pilot Study." *IEEE Access*, vol. 7, pp. 127055-127065, 2019, doi: 10.1109/ACCESS.2019.2933287.
.. [#] M.A. Delph II, S.A. Fischer, P.W. Gauthier, C.H. Martinez Luna, E.A. Clancy, and G.S. Fischer. "A Soft Robotic Exomusculature Glove with Integrated sEMG Sensing for Hand Rehabilitation." *IEEE 13th International Conference on Rehabilitation Robotics (ICORR)*, Jun. 2013, doi: 10.1109/ICORR.2013.6650426.
.. [#] \R. Bos, K. Nizamis, B.F.J.M. Koopman, J.L. Herder, M. Sartori, and D.H. Plettenburg. "A Case Study With Symbihand: An sEMG-Controlled Electrohydraulic Hand Orthosis for Individuals With Duchenne Muscular Dystrophy." *IEEE Transactions on Neural Systems and Rehabilitation Engineering*, vol. 28, no. 1, pp. 258-266, Jan. 2020, doi: 10.1109/TNSRE.2019.2952470.
.. [#] \V. Khoshdel, A. Akbarzadeh, N. Naghavi, A. Sharifnezhad, and M. Souzanchi-Kashani. "sEMG-based impedance control for lower-limb rehabilitation robot." *Intelligent Service Robotics*, vol. 11, pp. 97-108, 2018, doi: 10.1007/s11370-017-0239-4.
.. [#] M.A. Ozdemir, D.H. Kisaa, O. Gurena, and A. Akanb. "Dataset for multi-channel surface electromyography (sEMG) signals of hand gestures." *Data in Brief*, vol. 41, Apr. 2022, doi: 10.1016/j.dib.2022.107921.
.. [#] \Y. Luan, Y. Shi, W. Wu, Z. Liu, H. Chang, and J. Cheng. "HAR-sEMG: A Dataset for Human Activity Recognition on Lower-Limb sEMG." *Knowledge and Information Systems*, vol. 63, pp. 2791-2814, Sep. 2021, doi: 10.1007/s10115-021-01598-w.
^^^^^^^^^^
Heart Rate
^^^^^^^^^^
.. [#] \A. Galli, R.J.H. Montree, S. Que, E. Peri, and R. Vullings. "An Overview of the Sensors for Heart Rate Monitoring Used in Extramural Applications." *Sensors*, vol. 22, no. 11, 4035, doi: 10.3390/s22114035.
.. [#] J.F. Horton, P. Stergiou, T.S. FUNG, and L. Katz. "Comparison of Polar M600 Optical Heart Rate and ECG Heart Rate during Exercise." *Medicine & Science in Sports and Exercise*, vol. 49, no. 12, pp. 2600-2607, Dec. 2017, doi: 10.1249/MSS.0000000000001388.
.. [#] H.Y. Jan, M.F. Chen, T.C. Fu, W.C. Lin, C.L. Tsai, and K.P. Lin. "Evaluation of Coherence Between ECG and PPG Derived Parameters on Heart Rate Variability and Respiration in Healthy Volunteers With/Without Controlled Breathing." *Journal of Medical and Biomedical Engineering*, vol. 39, pp. 783-795, 2019, doi: 10.1007/s40846-019-00468-9.
.. [#] K.E. Speer, S. Semple, N. Naumovski, and A.J. McKune. "Measuring Heart Rate Variability Using Commercially Available Devices in Healthy Children: A Validity and Reliability Study." *European Journal of Investigation in Health, Psychology, and Education*, vol. 10, pp. 390-404, 2020, doi: 10.3390/ejihpe10010029.
.. [#] S.A. Ruiz-Alias, F. Garcia-Pinillos, V.M. Soto-Hermoso, and E.J. Ruiz-Malago. "Heart rate monitoring of the endurance runner during high intensity interval training: Influence of device used on training functions." *Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology*, vol. 237, no. 3, pp. 166-172, 2023, doi: 10.1177/17543371211037035.
.. [#] \F. Sartor, J. Gelissen, R. van Dinther, D. Roovers, G.B. Papini, and G. Coppola. "Wrist-worn optical and chest strap heart rate comparison in a heterogeneous sample of healthy individuals and in coronary artery disease patients." *BMC Sports Science, Medicine and Rehabilitation*, vol. 10, no. 10, 2018, doi: 10.1186/s13102-018-0098-0.
.. [#] \M. Schaffarczyk, B. Rogers, R. Reer, and T. Gronwald. "Validity of the Polar H10 Sensor for Heart Rate Variability Analysis during Resting State and Incremental Exercise in Recreational Men and Women." *Sensors*, vol. 22, no. 17, pp. 6536, 2022, doi: 10.3390/s22176536.
.. [#] \R. Gilgen-Ammann, T. Schweizer, and T. Wyss. "RR interval signal quality of a heart rate monitor and an ECG Holter at rest and during exercise." *European Journal of Applied Physiology*, vol. 119, pp. 1525-1532, 2019, doi: 10.1007/s00421-019-04142-5.
.. [#] \H. Chen, A. Dey, M. Billinghurst and R. Lindeman. "Exploring the Design Space for Multi-Sensory Heart Rate Feedback in Immersive Virtual Reality." *Proceedings of the 29th Australian Conference on Human-Computer Interaction (OzCHI 2017)*, Brisbane, QLD, Australia, 2017, doi: 10.1145/3152771.3152783.
.. [#] U.N. Hashim, L. Salahuddin, R.R.R. Ikram, U.R. Hashim, N.H. Choon, and M.H.N. Mohayat. "The Design and Implementation of Mobile Heart Monitoring Applications using Wearable Heart Rate Sensor." *International Journal of Advanced Computer Science and Applications (IJACSA)*, vol. 12, no. 1, 2021, doi: 10.14569/IJACSA.2021.0120120.
.. [#] \S. Gradl, M. Wirth, T. Zillig, and B.M. Eskofier. "Visualization of Heart Activity in Virtual Reality: a Biofeedback Application using Wearable Sensors." *2018 IEEE 15th International Conference on Wearable and Implantable Body Sensor Networks (BSN)*, Las Vegas, Nevada, USA, pp. 152-155, Mar. 2018, doi: 10.1109/BSN.2018.8329681.
.. [#] \C. Rockstroh, J. Blum, and A.S. Göritz. "Virtual reality in the application of heart rate variability biofeedback." *International Journal of Human-Computer Studies*, vol. 130, pp. 209-220, Oct. 2019, doi: 10.1016/j.ijhcs.2019.06.011.
^^^^^^^^^^^^^
Muscle Oxygen
^^^^^^^^^^^^^
.. [#] \S. Perrey and M. Ferrari. "Muscle Oximetry in Sports Science: A Systematic Review." *Sports Medicine*, vol. 48, pp. 597-616, 2018, doi: 10.1007/s40279-017-0820-1.
.. [#] \F. Oueslati, J. Boone, and S. Ahmaidi. "Respiratory muscle endurance, oxygen saturation index in vastus lateralis and performance during heavy exercise." *Respiratory Physiology & Neurobiology*, vol. 227, pp. 41-47, Jun. 2016, doi: 10.1016/j.resp.2016.02.008.
.. [#] D.P. Born, T. Stöggl, M. Swarén, and G. Björklund. "Near-Infrared Spectroscopy: More Accurate Than Heart Rate for Monitoring Intensity in Running in Hilly Terrain." *International Journal of Sports Physiology and Performance*, vol. 12, no. 4, pp. 440-447, 2017, doi: 10.1123/ijspp.2016-0101.
.. [#] \F. Contreras-Briceño, M. Espinosa-Ramírez, A. Rivera-Greene, C. Guerra-Venegas, A. Lungenstrass-Poulsen, V. Villagra-Reyes, R. Caulier-Cisterna, O.F. Araneda, and G. Viscor. "Monitoring Changes in Oxygen Muscle during Exercise with High-Flow Nasal Cannula Using Wearable NIRS Biosensors." *Biosensors*, vol. 13, no. 11, pp. 985, Nov. 2023, doi: 10.3390/bios13110985.
.. [#] D.P. Monteiro, G.A. Ribeiro-Samora, R.R. Britto, and D.A.G. Pereira. "Effects of modified aerobic training on muscle metabolism in individuals with peripheral arterial disease: a randomized clinical trial." *Scientific Reports*, vol. 9, Nov. 2019, doi: 10.1038/s41598-019-52428-7.
.. [#] A.W. Gardner, P.S. Montgomery, M. Wang, and B. Shen. "Association between calf muscle oxygen saturation with ambulatory function and quality of life in symptomatic patients with peripheral artery disease." *Journal of Vascular Surgery*, vol. 72, no. 2, pp. 632-642, Aug. 2020, doi: 10.1016/j.jvs.2019.09.057.
.. [#] \N. Cornelis, P. Chatzinikolaou, R. Buys, I. Fourneau, J. Claes, and V. Cornelissen. "The Use of Near Infrared Spectroscopy to Evaluate the Effect of Exercise on Peripheral Muscle Oxygenation in Patients with Lower Extremity Artery Disease: A Systematic Review." *European Journal of Vascular and Endovascular Surgery*, vol. 61, no. 5, May 2021, pp. 837-847, doi: 10.1016/j.ejvs.2021.02.008.
.. [#] \J. Montes, A.M. Goodwin, M.P. McDermott, D. Uher, F.M. Hernandez, K. Coutts, J. Cocchi, M. Hauschildt, K.M. Cornett, A.K. Rao, U.R. Monani, C.E. Garber, and D.C. De Vivo. "Diminished muscle oxygen uptake and fatigue in spinalmuscular atrophy." *Annals of Clinical and Translational Neurology*, vol. 8, no. 5, pp. 1086-1095, May 2021, doi: 10.1002/acn3.51353.
^^^^^^^^^^^^^
Oxygen Volume
^^^^^^^^^^^^^
.. [#] \R. Bahtraa, S. Crisarib, W.W. Dinatac, N. Susantod, and Y. Andria. "VO\ :sub:`2`\Max in Soccer Players: Comparison ofInterval Training and Continuous Running." *Journal of Sport Science and Education*, vol. 8, no. 1, 2023, pp. 46-53, doi: 10.26740/jossae.v8n1.p46-53.
.. [#] \D. Wen, T. Uteschc, J. Wud, S. Robertsone, J. Liuf, G. Hub, and H. Chena. "Effects of different protocols of high intensity interval training for VO\ :sub:`2`\max improvements in adults: A meta-analysis of randomised controlled trials." *Journal of Science and Medicine in Sport*, vol. 22, no. 8, Aug. 2019, pp. 941-947, doi: 10.1016/j.jsams.2019.01.013.
.. [#] M.S. Dasa, O. Friborg, M. Kristoffersen, G. Pettersen, J. Sundgot-Borgen, and J.H. Rosenvinge. "Accuracy of Tracking Devices' Ability to Assess Exercise Energy Expenditure in Professional Female Soccer Players: Implications for Quantifying Energy Availability." *International Journal of Environmental Research and Public Health*, vol. 19, pp. 4470, 2022, doi: 10.3390/ijerph19084770.
.. [#] \P. Maurice, J. Camernik, D. Gorjan, B. Schirrmeister, J. Bornmann, L. Tagliapietra, c. Latella, D. Pucci, L. Fritzsche, S. Ivaldi, and J. Babič. "Objective and Subjective Effects of a Passive Exoskeleton on Overhead Work." *IEEE Transactions on Neural Systems and Rehabilitation Engineering*, vol. 28, no. 1, pp. 152-164, doi: 10.1109/TNSRE.2019.2945368.
.. [#] L.L. Moberg, L.K. Lunde, M. Koch, A.T. Tveter, and K.B. Veiersted. "Association between VO\ :sub:`2max`\, handgrip strength, and musculoskeletal pain among construction and health care workers." *BMC Public Health*, vol. 17, no. 272, 2017, doi: 10.1186/s12889-017-4173-3.
.. [#] \F. Cuenca-Martínez, N. Sempere-Rubio, C. Varangot-Reille, J. Fernández-Carnero, L. Suso-Martí, P. Alba-Quesada, and R. La Touche. "Effects of High-Intensity Interval Training (HIIT) on Patients with Musculoskeletal Disorders: A Systematic Review and Meta-Analysis with a Meta-Regression and Mapping Report." *Diagnostics*, vol. 12, no. 10, pp. 2532, 2022, doi: 10.3390/diagnostics12102532.